[title] Install 2 Position Terminal Plugs
[* 10] ***NOTE: This step is not performed for the H2 Delta printer or when upgrading Rostock Max v1/v2 or Orion Delta printers.***
-[* 1] You will now install the supplied 2 position terminal plugs onto the remaining wires. (They are packed in the white box with the RAMBo board) The [document|23|HE280 Whip Diagram] shows the correct connections. These connectors can be found in the bag of terminals in the RAMBo box
+[* 1] You will now install the supplied 2 position terminal plugs onto the remaining wires. (They are packed in the white box with the RAMBo board.) The [document|23|HE280 Whip Diagram] shows the correct connections. These connectors can be found in the bag of terminals in the RAMBo box.
[* 9] Make sure the screws in the terminal blocks are as loose as possible to prevent strands of the wires being forced under the connectors.
-[* 1] The orange wire (Layer Fan) will be inserted into one of the 2 position terminal blocks.
-[* 1] The red and black wires (Hot End 12v power) will be inserted into the other 2 position terminal block.
-[* 9] Be sure to get the polarity correct (as shown in the diagram
-[* 9] Tighten the screw terminals as tight as possible, including the vacant position on the terminal block with the orange wire (layer fan).
+[* 1] Insert the orange wire (Layer Fan) into one of the 2 position terminal blocks.
+[* 1] Insert the red and black wires (Hot End 12v power) into the other 2 position terminal block.
+[* 9] Be sure to get the polarity correct as shown in the diagram.
+[* 9] Tighten the screw terminals as tight as possible, including the vacant position on the terminal block that has the orange wire (layer fan).