Skip to main content
  1. 1. Goto Settings
    • 1. Goto Settings

    • 2. Then System Editor

    • 3. Click on config.g

  2. We do not recommend higher than 1.5Amps (or a value of 1500). Motors can be damaged.  We normally start at 1A (or a value of 1000).
    • We do not recommend higher than 1.5Amps (or a value of 1500). Motors can be damaged. We normally start at 1A (or a value of 1000).

    • See the comment to the right of the semi colon? On the line with command M906

    • Change X Y Z values to 1500. That means 1.5 Amps to each axis motor.

    • Extruder currents are the E settings. A colon separates extruder 1 and extruder 2. Keep the syntax (format) E1500:1500

    • Select '"Save Changes"' and reboot the Duet. The Duet will read config.g on startup and your new settings will be in effect.

Finish Line

SeeMeCNC

Member since: 10/04/2016

562,208 Reputation

16 Guides authored

0 Comments

Add Comment

View Statistics:

Past 24 Hours: 0

Past 7 Days: 0

Past 30 Days: 0

All Time: 505